Batteries first. A generator behind them.
The generator starts itself · at the end of the gardenVisualisation
The batteries carry the house through most power cuts. For longer ones, a quiet standby generator refills them.
Not every battery can be refilled.
A battery and generator system gives a house days of backup, not hours. We are NU Projects, design and build in Fulham SW6 since 2010. We design both together, so the generator can refill the batteries. Call 020 7731 6841 to talk it through.
This is the point most installers miss. Some popular home batteries do not charge from a generator at all.
The two then run as separate systems. The house falls back to the generator alone once the battery is empty.
A generator-ready platform works differently. When the batteries run low, it starts the generator by itself. The generator refills the batteries, then stops.
So the platform has to be chosen around the generator from day one.
What we design with the generator
- Automatic start from the battery system
- An acoustic enclosure, sized for the neighbours
- Its own earth, as the wiring rules require
- A changeover that can never feed the grid
- A safe fuel supply, gas or bunded diesel
- A noise assessment where planning asks for one
A battery room for a large house.
One possible set-up, designed into the basement from the first drawings.

Setting one up in the UK
- We check the supply first. Single-phase and three-phase houses need different systems.
- A lift, pool plant or fast car charger usually means three-phase backup.
- A large house can have whole-home backup of 40 to 60 kW.
- Good systems switch over in a fraction of a second.
- Battery storage indoors is capped at 40 kWh. Larger stores are split or sit outside.
- A basement battery room needs its own route to the outside.
- It also needs fire separation and a smoke alarm to BS 5839-6.
- Batteries never go in bedrooms, lofts or on an escape route.
- Each cabinet can weigh 130 kg, so floors and access are checked.
- Not every battery can be refilled by a generator. We choose the platform first.
- A generator always sits outside, and usually needs planning for noise.
- A fixed gas or diesel generator of 16 to 20 kVA refills it.
- Larger systems need UK Power Networks approval. Allow four to eight weeks.
- Installers must be MCS certified and give a six-year insured guarantee.
- Work is certified to the 2026 amendment of the Wiring Regulations.
- Installed batteries carry 0% VAT until 31 March 2027.
A smaller generator, running less.
The batteries take the surges, such as pumps and motors starting. So the generator only has to cover charging and the base load.
That usually means a smaller set than a generator on its own. It runs for a few hours, then rests.
Less running means less noise, less fuel and less wear.
Gas or diesel.
A mains gas generator needs no fuel deliveries. But a standard domestic gas supply limits its size. A Gas Safe engineer checks the supply first.
A water-cooled diesel is the quieter choice, with a bunded tank. It suits houses that want longer cover.
Either way, the generator runs outdoors, in an acoustic enclosure. Its exhaust must never reach the house.
The street goes dark. Your home carries on.
From a survey to handover.
- 01
Survey
We read the supply, the loads and where the kit can go.
- 02
Design
Battery, generator, placement and fire safety are designed together.
- 03
Approvals
Network approval, and planning or listed building consent where needed.
- 04
Build
The battery store, wiring and changeover are built with your project.
- 05
Test and hand over
We cut the mains on purpose and show you the house carry on.
What owners ask.
Can my existing battery work with a generator?
Sometimes, but often only as a separate system. We check the model before suggesting anything.
Will the neighbours hear it?
A well-enclosed set is quiet, but not silent. Placement and the enclosure are designed around the nearest windows.
Does a generator need planning permission?
Often, in a conservation area or near a boundary. The council may ask for a noise assessment.
How often does it run?
Only in a long power cut. It also runs a short test each month.
Is VAT charged on the generator?
Yes, at the standard rate. Installed batteries carry 0% VAT until 31 March 2027.
What does it cost?
It is a specialist service, so we price it after a survey.
Related services
Talk to Nick about backup power.
Your name and one way to reply are enough. Tell us about the house if you like.